Corrections of model parameters 1. Cai et al. (1997) J. Neurophysiol. The following parameter correction is needed: axon Na, gNamax = 0.37 Msh = -2.3 axon K, Nfac = 0.25 A complete description of the parameters after correction: node 0 axon leak 2.56826e-09 S -53 mV gNa 0.37 S 55 mV, Msh -2.3, Hsh -10.8, Mfac 0.1315, Hfac 0.1315 gK 0.02 S -80 mV, Nsh 2.65, Nfac 0.25 node 1 soma Iinj 1.8 nA, 10-50 ms DC leak 3.217e-08 S -70.13 mV gNa 0.01 S 55 mV, Msh 1.8, Hsh -10, Mfac 0.1315, Hfac 0.1315 gK 0.01 S -80 mV, Nsh -1.3, Nfac 0.25 gKLT 0.01 S -77 mV, Bsf 10, Bfac 0.75, a0, b0, 0.03 0.042, Ka, Kb, 14.5 31.25 gIH 0.02 S -45 mV, IHsf 0, Ks 5 Besides, "Ohm/cm2" and "Ohm/cm" were incorrectly converted to "Ohm*cm2" and "Ohm*cm" during printing. 2. Cai et al. (2000) J. Neurophysiol. Kb should be 3.7 instead of -3.7 using the formula in the paper.